[ Team LiB ] Previous Section Next Section

12.5 Simulink Functions

SIMULINK has a number of built-in functions to perform ratio, selective, and split-range control. Examples are shown here.

Product

Can be used for ratio control

MinMax

Can be used for high or low selection

Switch

Can be used for switching between alternatives

Saturation

Can be used for split-range control, and controller saturation

graphics/12fig06a.gif

An example SIMULINK block diagram to implement a split-range jacket temperature controller from Example 12.1 is shown in Figure 12-7. Since this has been formulated in deviation variable form, the output of the jacket temperature controller ranges from –50 to 50%. Saturation elements are used for the cold and hot valve positions.

Figure 12-7. SIMULINK implementation of a split-range strategy for a jacket temperature controller.

graphics/12fig07.gif

    [ Team LiB ] Previous Section Next Section